Using a vacuum rubber compression molding press mainly follows a sequence of loading material → closing mold → vacuuming → pressing/curing → demolding. The core difference from an ordinary press is that before and during compression, a vacuum hood (or vacuum chamber) evacuates air from the mold cavity, reducing bubbles and defects in the product.


Standard Operating Steps


1. Preparation and Loading

First, preheat the mold to the curing temperature required for the rubber compound. Place the pre-weighed rubber blank into the open mold cavity. Note that this is compression molding (material placed in the open mold before closing), not injection molding.


2. Close Mold and Engage Vacuum

Close the mold, or move it into the press working area. Lower the vacuum hood to seal the mold area, then start the vacuum pump to evacuate until the set vacuum level is reached (some equipment uses vacuum levels around -96 KPa as reference). The vacuum removes air trapped between the rubber blank and the mold cavity.


3. Pressurize and Vent

While maintaining vacuum (or after reaching vacuum), the main cylinder pressurizes to compress the mold. To help residual gas escape, the machine typically performs "bumping" (briefly opening and re-closing the mold) according to preset parameters, then continues applying full pressure for curing.


4. Curing and Demolding

Maintain pressure and temperature for the curing time specified for the rubber compound. Once curing is complete,

 release pressure, open the vacuum hood, open the mold, and remove the finished part.


Key Parameters and Safety


· Temperature: Must match the vulcanization system of the rubber compound. Insufficient temperature leads to undercure, 

while excessive temperature may cause scorching.

· Vacuum Level: Directly affects bubble removal. If vacuum level is insufficient, check the sealing ring of the vacuum hood 

and piping for leaks.

· Pressure: Determined by product area and mold structure; too low pressure causes insufficient filling and flash.

· Safety: The mold and platen temperatures are very high during operation; wear heat-resistant gloves. 

Never reach hands into the mold area while the machine is running or under pressure.


If you are using a specific brand or model of equipment, the operation panel and vacuum hood design may differ;

 it is recommended to refer to the equipment's nameplate or manual for confirmation.

If you encounter any issues while operating the equipment, please contact us at: jocelyn@japlau.com


Contact Us
  • Name: Jocelyn / Karl/ Jap/ Timmy /Abby
  • Tel.: +8618603071612
  • Cellphone: 0086 186 0307 1612
  • Email: Info@japlau.com
  • Skype: jocelyn-zl
  • WhatsApp: +86 186 0307 1612
  • Add.: DongBao Industry Zone, Sha Jing Street, Bao 'an District, ShenZhen

Copyright © JAPLAU All Rights Reserved     Technical Support:     https://new.cnzz.com/v1/login.php?siteid=1278629928   Sitemap